4-5

Gas

Pressure

Natural Lacq
(G20) under 20 mbar

7 mbar

Natural Gronique*
(G25) under 25 mbar

12 mbar

Propane
(G31) under 37 mbar

22,2 mbar

CE Standard for

Burner Gas Pressure

* Belgian G25 = 7,0 mbar

Gas

Pressure

Natural

3.5" WC

0.87 kPa

8.718 mbar

Propane

8.25" WC

2.05 kPa

20.55 mbar

Non-CE Standard for

Burner Gas Pressure

6.

To adjust the burner gas pressure, remove the cap from the gas valve regulator and use a flat-tipped
screwdriver to adjust the regulator to obtain the correct pressure.

Non-CE

Valve

Earlier Model CE Valve

Later Model

CE Valve

GAS VALVE REGULATOR CAP

7. Place the power switch (and the gas valve in non-CE cookers) in the OFF position. Remove the fitting

from the pressure tap hole and reinstall the pressure tap plug.

4.5

Measuring Flame Current

When the burner flame is properly adjusted, it will produce a current between 2.5 µA and 3.5 µA. Flame
current is measured by placing a microamp (not milliamp) meter in series with the white sensing wire on one
of the ignitors. This is accomplished as follows:

1. Place the power switch in the OFF position.

2. Disconnect the sensing wire from one of the burner ignitors and connect it to the positive lead of the

meter. Connect the negative lead of the meter to the terminal from which the sensing wire was re-
moved.

3. Place the power switch in the ON position to light the burners. After the cookpot temperature reaches

200

0

F (93

0

C), wait at least one minute before checking the reading. NOTE: The closer the unit is to

normal operation temperature, the more accurate the reading will be.

4.6

Controller Simmer Mode Adjustment

NOTE: The controller simmer temperature is adjustable form 185

°

F to 215

°

F (85

°

C to 102

°

C). There are

two versions of this controller; one is adjusted by programming, the other is manually adjusted. To