Frymaster GC User Manual

Page 26

Advertising
background image

4-6

determine which version of the controller you have, turn the controller off by pressing the power

switch.

The display will go blank. Press the Simmer Mode

(right thermometer icon) switch. If Code appears in

the display, the setpoint is changed via programming; if not, skip to Manual Adjustment on the next
page.

1. Press 1, 6, 5, 0 to enter the programming mode. The currently programmed simmer setpoint will be

displayed. If the setpoint is not correct, enter the desired setpoint (for example, press 2, 0, 0 to pro-
gram the simmer setpoint to 200

°

).

2. Press the Simmer Mode

switch again to lock the setpoint, then press the power

switch to turn

the controller on and return to the normal operating mode.

Manual Adjustment

1. With the unit in the simmer mode, place the tip of a good grade thermometer near the temperature

probe and determine the actual water temperature in degrees Fahrenheit. If the temperature is within
±5

°

F (2

°

C) of the desired simmer temperature, nothing more needs to be done. If it is not within ±5

°

F

(2

°

C) of the desired temperature, perform Steps 2 through 5.

2. With the unit in the Simmer Mode, open the control panel by removing the screws in the upper corners

and tilting the panel out.

3. Remove the black rubber plug from the top of the controller housing.

4. Using a small, flat-tipped screwdriver, turn the adjusting screw to change the simmer setpoint. A ¼

turn will change the setpoint about 10

°

F (4

°

C). (You will have to experiment with the direction of

rotation to determine which way to turn to raise or lower the temperature). Wait at least 5 minutes, then
recheck actual water temperature. Repeat this step until the water temperature is within ±5

°

F (2

°

C) of

desired temperature.

5. Replace the plug in the controller, close the control panel, and replace the screws removed in Step 2.

Advertising