Frymaster GC User Manual

Page 28

Advertising
background image

5-2

5.2

Operator Troubleshooting Guides

Problem

Probable Causes

Corrective Action

A. Ignition module lockout (the

burners failed to light within 4
seconds).

Indicator: Red trouble light on
control panel is illuminated.

A. Turn the controller OFF. Open

the control panel by removing
the screws in the upper corners.
If there are two ignition mod-
ules, check for blown 2-amp
fuses and replace as necessary.
Close the control panel and press
the power switch. Wait at least
4 minutes.

B. Dirty water level sensors. (If the

computer does not sense sufficient
water in the cookpot, it will not
allow the burners to fire.)

B. Remove the probe block cover

and clean the sensors using a
Scotchbrite™ or similar pad and
a solution of detergent and
water.

C. Failed controller.

Test: If another controller known
to be working is available, substi-
tute the working controller for the
suspect controller. If the burners
light, the controller has failed.

C. Order replacement controller

from FASC or distributor.

BURNERS DO NOT

LIGHT

(Main gas supply

valve verified to be

open, the gas valve in

Non-CE units is

verified to be ON, and

power switch is

verified to be ON.)

D. Failed ignition module or gas

valve, or broken or loose wiring.

C. Call FASC.

A. Dirty water level sensors. (If the

sensors are dirty, they may cause
the controller to “think” the
cookpot is full.)

A. Remove the probe block cover

and clean the sensors using a
Scotchbrite™ or similar pad and
a solution of detergent and
water.

B. Failed controller.

Test: If another controller known
to be working is available,
substitute the working controller
for the suspect controller. If the
unit begins to fill, the controller
has failed.

B. Order replacement controller

from FASC or distributor.

ON UNIT WITH

AUTOFILL,

COOKPOT DID

NOT FILL WHEN

UNIT WAS

TURNED ON

(Water supply to unit

verified to be ON.)

C. Shorted upper water level sensor,

failed water solenoid valve, or
loose/broken wiring.

C. Call FASC.

Advertising