Frymaster GC User Manual

Page 24

Advertising
background image

4-4

TYPICAL NON-CE BLOWER ASSEMBLY

TYPICAL CE BLOWER ASSEMBLY

4.4

Adjusting the Burner Gas Pressure

DANGER

Frymaster recommends that ONLY qualified service personnel perform this task.

1. On Non-CE cookers, ensure that the gas valve knob is in the OFF position.

2. Remove the pressure tap plug from the gas valve assembly.

Typical Non-CE

Valve Assembly

Typical CE

Valve Assembly

Pressure Tap Plug

3. Insert the fitting for a gas pressure-measuring device into the pressure tap hole

4. On NON-CE cookers only, place the gas valve in the ON position.

5. Place the power switch in the ON position. When the burner has lit and burned steadily for at least one

minute, compare the gas pressure reading to the pressure for the corresponding gas in the appropriate
table below.

Advertising