Po d o per at io ns, Mj1 test – Fuji Bikes FEH381 User Manual

Page 82

Advertising
background image

6

2. Main Menu Screen

6-9

P

O

D

O

per

at

io

ns

RS-422 signal test

1.

Slide the slide switch on the POD to the lower position for RS-422.

2.

Turn on the [MJ2] and [RS485] switches under [Communication Port].

3.

Check the signals [+RD], [

−RD], [+SD] and [−SD]. Wire inside MJ2 as shown below.

4.

Press the [Self-Loop Test] switch. When the [OK] lamp lights up, the test is successfully
completed.

* If the [NG] lamp lights up, consult your local distributor.

MJ1 Test

RS-232C signal test

1.

Turn on the [MJ1] and [RS232C] switches under [Communication Port].

2.

Check the signals [RD] and [SD]. Wire inside MJ1 as shown below.

RS232C

RS485

Communication Port

CN1

MJ1

MJ2

Signal

Name

Pin No.

+SD

1

−SD

2

+RD

7

−RD

8

MJ2

Self-Loop

Test

CTS

RTS

NG

OK

CTS

RTS

NG

OK

Self-Loop

Test

CN1

MJ1

MJ2

RS232C

RS485

Communication Port

Signal

Name

Pin No.

RD

7

SD

8

MJ1

Advertising