9 system characteristics – Furuno FS-1570 User Manual

Page 21

Advertising
background image

1 OPERATIONAL OVERVIEW

1-7

1.9 System Characteristics

1.9.1 Equipment priority

Equipment priority order is as below.

1. DMC
2. Each control unit and control unit sending distress alert
3. Control unit 1 – routine use
4. Control unit 2 – routine use
5. NBDP

1.9.2 Controls become inoperative

Controls become inoperative in the following conditions:

•

Controls of idle control unit in the two-control unit system when other control unit goes
OFF HOOK.

•

Controls of idle control unit in the two-control unit system when other control unit
switches to the DSC mode.

•

Distress received by DMC (Distress Message Controller).

•

NBDP is scanning or communicating.

•

Distress alert or distress relay is transmitted.

•

Call other than distress is transmitted (transmission time about 8 seconds). If it becomes
necessary to unlock the keyboard before the message is transmitted, press the
[CANCEL] key to cancel the call.

1.9.3 Controls become operative

Controls become operative in the following conditions:

•

DISTRESS button is pressed.

•

Control unit having highest priority is operated.

•

Other control unit in two-control unit system goes ON HOOK.

•

Distress received by DMC is acknowledged.

•

NBDP stops scanning or communicating.

Advertising