3 pre-connection preparations (cont.) – Frymaster 45 User Manual
Page 16

MASTER JET SERIES ATMOSPHERIC GAS FRYERS
CHAPTER 2: INSTALLATION INSTRUCTIONS
2-6
2.3 Pre-Connection Preparations (cont.)
6. Verify the minimum and maximum gas supply pressures for the type of gas to be used in
accordance with the accompanying tables:
Model
Gas Type
G20
G25
G31
G20
G25
G31
G20
G25
G31
Pressure
(mbar)
1
20
20-25
37-50
20
20-25
37-50
20
20-25
37-50
Number
of
Orifices
9
9
9
18
18
18
21
21
21
Manifold
Pressure
9
13,5
22,5
7,5
10
20,6
7,5
10
14,9
Air Flow
(m
3
/H)
1,70
1,70
1,05
1,40
Table 1: CE Standards for Incoming Gas Pressures
MJ35/J2X CE
MJ45 CE
MJCF/J65 CE
4,18
2,35
1,40
0,86
1,40
1,40
1
(mbar) = 10,2 mm CE
Orifice
Size
0,95
2,50
3,06
1,51
3,10
3,58
1,80
3,62
Table 2: Non-CE Standard
for Incoming Gas Pressures
Gas
Minimum
Maximum
Natural
6" W.C.
1.49 kPa
14.93 mbar
14" W.C.
3.48 kPa
34.84 mbar
LP
11" W.C.
2.74 kPa
27.37 mbar
14" W.C.
3.48 kPa
34.84 mbar
7. For fryers equipped with a built-in filter system and/or basket lifts, plug the electrical cord(s) into
a power receptacle behind the fryer.