MASTER JET SERIES ATMOSPHERIC GAS FRYERS

CHAPTER 2: INSTALLATION INSTRUCTIONS

2-6

2.3 Pre-Connection Preparations (cont.)


6. Verify the minimum and maximum gas supply pressures for the type of gas to be used in

accordance with the accompanying tables:

Model

Gas Type

G20

G25

G31

G20

G25

G31

G20

G25

G31

Pressure

(mbar)

1

20

20-25

37-50

20

20-25

37-50

20

20-25

37-50

Number

of

Orifices

9

9

9

18

18

18

21

21

21

Manifold

Pressure

9

13,5

22,5

7,5

10

20,6

7,5

10

14,9

Air Flow

(m

3

/H)

1,70

1,70

1,05

1,40

Table 1: CE Standards for Incoming Gas Pressures

MJ35/J2X CE

MJ45 CE

MJCF/J65 CE

4,18

2,35

1,40

0,86

1,40

1,40

1

(mbar) = 10,2 mm CE

Orifice

Size

0,95

2,50

3,06

1,51

3,10

3,58

1,80

3,62

Table 2: Non-CE Standard

for Incoming Gas Pressures

Gas

Minimum

Maximum

Natural

6" W.C.

1.49 kPa

14.93 mbar

14" W.C.
3.48 kPa

34.84 mbar

LP

11" W.C.
2.74 kPa

27.37 mbar

14" W.C.
3.48 kPa

34.84 mbar



7. For fryers equipped with a built-in filter system and/or basket lifts, plug the electrical cord(s) into

a power receptacle behind the fryer.