1 start-up procedure (cont.) – Frymaster 45 User Manual

Page 25

Advertising
background image

MASTER JET SERIES ATMOSPHERIC GAS FRYERS

CHAPTER 3: OPERATING INSTRUCTIONS

3-3

3.1 Start-Up Procedure (cont.)


LIGHTING THE PILOT ON NON-CE FRYERS

1. Ensure power to the unit is OFF, and then turn the gas valve knob to the OFF position. Wait at

least 5 minutes, and then rotate the gas valve knob to the PILOT position (see Figure 1).

Lighting the Pilot

OFF

ON

PILO

T

OFF

ON

PILO

T

Figure 1

Figure 2

2. Push the knob in and light the pilot. (If the fryer is equipped with a piezo ignitor, repeatedly

press the piezo ignitor button while depressing the gas valve knob until the pilot lights.)
Continue to hold the knob in for about 60 seconds after the flame appears on the pilot. Release
the knob. The pilot should remain lit.

CAUTION

If the pilot fails to remain lit, turn the gas valve knob to the OFF position and wait at

least five minutes before attempting to re-light.



LIGHTING THE PILOT ON FRYERS WITH CE HONEYWELL GAS VALVES

1. Ensure power to the unit is OFF, and then press the OFF (red) button. Wait 5 minutes.















OFF Button

PILOT Button

CE Honeywell gas valve (24V)

Advertising