5 converting to another gas type (cont.) – Frymaster 45 User Manual

Page 21

Advertising
background image

MASTER JET SERIES ATMOSPHERIC GAS FRYERS

CHAPTER 2: INSTALLATION INSTRUCTIONS

2-11

2.5 Converting to Another Gas Type (cont.)

CE Gas Conversion Instructions


1. Between G20- and G25-type Natural Gas, adjust the gas pressure at the regulator. (Refer to the

CE Standard Burner Manifold Gas Pressure Chart.) Do not change the orifice or pilot.

2. Between a 2

nd

family gas (G20 or G25) and a 3

rd

family gas (G31 Propane):

a.

Change

the

orifices.

b.

Change

the

pilot.

c. Change the gas valve regulator or the gas valve.

d. Adjust the manifold pressure.

3. Affix the new label included with the conversion kit next to the existing rating plate stating that

the gas type has been converted. Remove any references to the previously used gas from the
existing rating plate.

4. If the destination language changes, replace the labels. Call your local service agency or kitchen

equipment supplier for a label kit. The language of reference will be on the corner of the label.

The following gas-conversion components and kits are available from your FASC:

CE Only:

Propane (G31) to Natural (G20/G25)

Regulator only: P/N 810-1292

Pilot, regulator, and orifices kit: P/N 826-1478 (MJCFE); P/N 826-1203 (MJ45E)


Natural (G20/G25) to Propane (G31)

Regulator only: P/N 810-1292

Pilot, regulator, and orifices kit: P/N 826-1204 (MJCFE); P/N 826-1202 (MJ45E)

MJ35 Only: There are no CE conversion kits available for the 35 Series. Honeywell G31 (propane) gas
valves can be adjusted for G20 and G25 (natural) gases, but G20 and G25 gas valves cannot be
adjusted for G31. Therefore, if converting from a G20 or G25 gas to G31 gas, in addition to the pilot and
orifices, the gas valve must be changed. The table below identifies the parts required to convert from one
gas family to another:

2

nd

Family (G20/G25) to 3

rd

Family (G31)

3

rd

Family (G31) to 2

nd

Family (G20/G25)

826-1354 (package of 10 burner orifices)

826-1353 (package of 10 burner orifices)

810-0427 pilot orifices (2 Required)*

810-0426 pilot orifices (2 Required)*

807-2121 CE Gas Valve (Millivolt)

Adjust Gas Valve (No Replacement Required)

Conversion Rating Label 802-2144

* Quantity required is one unless otherwise noted.

Advertising