Frymaster 45 User Manual

Page 50

Advertising
background image

MASTER JET SERIES ATMOSPHERIC GAS FRYERS

CHAPTER 6: OPERATOR TROUBLESHOOTING

6-7

6.4 Troubleshooting the Built-In Filtration System (cont.)

A. Plugged openings or solidified

shortening in the Power Shower.

Test: Look for oil or shortening
squirting out around the Power
Shower gasket. If so, Power
Shower is obstructed.

A. Clean the Power Shower per

instructions in Chapter 5 of this
manual.

B. Missing/worn O-rings and gasket

on Power Shower.

B. Verify that O-rings and gasket are

present and in good condition.

Power Shower is not

spraying properly.

C. Missing paper in filter pan. (This

causes too much pressure in the
oil return lines, resulting in a
strong flow through the Power
Shower, but also squirting of oil
from around the gasket.)

C. Verify that filter paper is properly

installed in the filter pan.


6.5 Troubleshooting Abnormal Burner Operation

PROBLEM PROBABLE

CAUSES CORRECTIVE

ACTION

Fryer is operating

normally, but flames

are rolling out of the

front of the burner.

Obstructed gas valve vent tube.

Shut the fryer down and clean the gas
valve vent tube in accordance the
instructions on Page 5-4 – 5-5 of this
manual.

Advertising