MASTER JET SERIES ATMOSPHERIC GAS FRYERS

CHAPTER 6: OPERATOR TROUBLESHOOTING

6-4

6.3 Troubleshooting Fryers with Thermostat Controls

PROBLEM Probable

Causes

Corrective

Action

A. Pilot is not lit.

A. Light pilot per instructions in

Chapter 3 of this manual.


B. Drain valve not fully closed.


B. Verify drain valve is fully closed.

C. No electrical power to unit.

C. Verify that unit is correctly

plugged in and that circuit breaker
is not tripped.

Burner does not

light.

D. No gas being supplied to unit.

D. Verify that the gas line

connections are properly
connected, that any cutoff valves
between the fryer and the gas
main are open, and that the main
gas cutoff valve is open.

Unit will not go into

melt cycle or stays in

melt cycle

continuously.

Failed melt cycle switch.

Defective melt cycle circuit board

Melt cycle switch or melt-cycle
circuit board must be replaced. Call
FASC.

Fryer never reaches

frying temperature.

Failed thermostat or thermostat out of
calibration.

Isolating the problem requires
additional troubleshooting beyond the
scope of operator troubleshooting.
Call FASC.