Setting method 1: by gyrocompass specifications – Furuno FR1500 Mk3 User Manual

Page 36

Advertising
background image

4-4

Setting method 1: by gyrocompass specifications

1) Gyrocompass type

2) Frequency

Gyrocompass
type

SW

1-4

SW

1-5

SW

1-6

JP1

Frequency

SW

1-7

SW

1-8

Remarks

AC synchronous

OFF

OFF

OFF #1,

#2, #3

50/60Hz

OFF

OFF

AC synchronous
pulsating current

DC synchronous

OFF

OFF

OFF #2,

#3, #4

400Hz

ON

OFF

AC synchronous
pulsating current

DC step

ON

OFF

OFF #4,

#5, #6

500Hz

OFF

ON

AC synchronous
pulsating current

Full-wave
pulsating current

OFF

ON

OFF #4,

#5, #6

DC

ON

ON

DC synchronous
DC step

Half-wave
pulsating current

ON

ON

OFF #4,

#5, #6

3) Rotor voltage
(between R1 & R2)

4) Stator voltage
(between S1 and S2)

Rotor voltage

SW 2-1

JP3

Stator voltage

SW 2-2

SW 2-3

JP2

20V to 45V AC

ON

#2

20V to 45V AC, or
20V to 60V DC

ON

OFF

#2

30V to 70V AC

OFF

#2

40V to 90V AC

ON

#1

20V to 45V AC, or
20V to 60V DC

OFF

OFF

#2

60V to 135V AC

OFF

#1

40V to 90V AC

ON

OFF

#1

60V to 135V AC

OFF

OFF

#1

5) Ratio

6) Supply voltage

Ratio

SW1-1

SW 1-2

SW1-3

Supply voltage

JP4

JP5

360x

OFF

OFF

OFF

20V to 45V AC, or
20V to 60V DC

#2

#2

180x

ON

OFF

OFF

90X

OFF

ON

OFF

30V to 135V AC, or
40V to 100V DC

#1

#1

36X

ON

ON

OFF

7) AD-10 format data
Tx interval

8) NMEA-0183
Tx interval

Select data transmitting interval for ports 1 to 6 by jumper wires
JP6 and JP7.

Tx
interval

SW2-4

Note: The Tx interval is available in 25 msec or 200 msec. 25

msec is for radar; 200 msec is for all other equipment.

2 seconds

ON

1 second

OFF