4-8

Adjustment

1. Set the controls on the radar as follows:

Range: 6 nm
A/C SEA, A/C RAIN, GAIN: fully counterclockwise

2. Connect a digital multimeter, set to 10 VDC range, to the following points on

the ARP-17 Board: (+), TP11 (VS+), (-), TP10 (VS-).

Figure 4-5 ARP-17 Board

3. Adjust potentiometer R121 (“OFFSET”) on the ARP-17 Board to show +0.09

to 0.13 V.

4. Set the radar controls and switches as follows:

Range: 24 nm
A/C SEA, A/C RAIN, GAIN: fully counterclockwise
Interference rejector: OFF
Echo stretch: OFF

5. Turn on the power while pressing the GAIN control. Press [MENU] [0] [0] [0] [0]

[6] [6] [0] [0] to display the SET UP 2 menu.

Figure 4-6 SET UP 2 menu