2. Inspect the filter pan connection fitting to ensure that

both O-rings are in good condition (see Figure 2).

3. Then in reverse order, place the metal filter screen in

the center of the bottom of the pan, then lay a sheet of
filter paper on top of the screen, overlapping on all
sides (see Figure1). If using a filter pad, ensure the
rough side of the pad is up and lay the pad over the
screen, making sure that the pad is in between the
embossed ridges of the filter pan.

4. Position the hold-down ring over the filter paper and

lower the ring into the pan, allowing the paper to rest
on the sides of the filter pan (see Figure 3).

5. When the hold-down ring is in position, if using filter

paper, sprinkle one packet of filter powder evenly
over the paper. (See Figure 4)

6. Replace the crumb tray in the filter pan, then push the

filter pan back into the fryer, positioning it under the
drain.

Figure 2

Figure 3

Figure 4

4.1.2 Preparation for Use with the Magnasol Filter Assembly

1. Pull the filter pan out from the cabinet

and remove the crumb tray and
Magnasol filter assembly (see Figure 5).
Clean as directed in section 4.4

The pan cover must not be removed
except for cleaning, interior access, or to
allow a shortening disposal unit (SDU)
to be positioned under the drain.

NOTE: Refer to Section 4.4 for
instructions on how to disassemble and
reassemble the Magnasol filter screen
assembly.

2. Inspect the fitting on the bottom of the

Magnasol filter assembly to ensure that
the O-ring is present and in good
condition. (See Figure 6)

3. Inspect the filter pan connection fitting

to ensure that both O-rings are present
and in good condition. (See Figure 2
above).

4. Replace the Magnasol filter assembly in

the filter pan, ensuring that the fitting on
the bottom of the assembly is securely

seated in the port in the bottom of the pan.
Sprinkle one packet of the Magnasol XL filter
powder evenly over
the screen.

5. Replace the crumb tray, and then push the filter

pan back into the fryer, positioning it all the way
to the back of the cabinet.

Figure 5

Figure 6

Inspect the filter
screen O-ring.

Inspect the filter
connection fitting
O-rings.

Advertising