Problem

Probable Causes

Corrective Action

Controller displays

TOPOFF OIL

EMPTY /

CONFIRM

Top off system out of oil.

Fill top off system with oil and press the
S (CONFIRM) button.



6.2.6 Error Log Codes (For 3000 Controller Only)

Code ERROR

MESSAGE

EXPLANATION

E03

ERROR TEMP PROBE FAILURE

TEMP Probe reading out of range

E04

HI 2 BAD

High limit reading is out of range.

E05

HOT HI 1

High limit temperature is past more than 410°F
(210°C), or in CE countries, 395°F (202°C)

E06

HEATING FAILURE

A component has failed in the high limit circuit
such as controller, interface board, contactor or
open-high limit.

E07

ERROR MIB SOFTWARE

Internal MIB software error

E08

ERROR ATO BOARD

ATO board connection lost; ATO board failure

E15

ERROR MIB BOARD

Cooking controller detects MIB connections lost;
Check software version on each controller. If
versions are missing, check CAN connections
between each controller; MIB board failure

E17

ERROR ATO PROBE

ATO RTD reading out of range

E20

INVALID CODE LOCATION

SD card removed during update

E21

CHANGE FILTER PAPER

25 hour timer has expired. Change filter paper
and follow prompts.

E22

OIL IN PAN ERROR

Oil may be present in the filter pan.

E25

RECOVERY FAULT

Recovery time exceeded maximum time limit.
Recovery time should not exceed 1:40 for
electric.

E27

LOW TEMP ALARM

Oil temperature has dropped 30°F (17°C) lower
than setpoint in idle mode or 45°F (25°C) in cook
mode. (This message may appear if a product is
dropped and the start cook button is not pressed
immediately or if too large of cook loads are
dropped.)

6.2.7 HIGH-LIMIT TEST MODE

The high-limit test mode is used to test the high limit circuit. The high-limit test will destroy the oil.
It should only be performed with old oil. Shut the fryer off and call for service immediately if the
temperature reaches 460°F (238°C) without the high-limit tripping and the computer displays

high

LIMIT FAILURE alternating with DISCONNECT POWER with an alert tone during testing.

The test is cancelled at any time by turning the fryer off. When the fryer is turned back on, it returns
to the operating mode and displays the product.

1. Press and hold the check (9) button until

MAIN MENU is displayed followed by PRODUCT

SETUP.

Advertising