HA configuration

System config

Cluster Members

When the cluster is operating, you can select Cluster Members to view the status of all
FortiGate units in the cluster. Status information includes the cluster ID, status, up
time, weight, and monitor information. For more information, see

“To view the status of

each cluster member” on page 95

.

Mode

All members of the HA cluster must be set to the same HA mode.

Group ID

The group ID range is from 0 to 63. All members of the HA cluster must have the
same group ID.
When the FortiGate units in the cluster are switched to HA mode, all of the interfaces
of all of the units in the cluster acquire the same virtual MAC address. This virtual
MAC address is set according to the group ID.

Table 3

lists the virtual MAC address

set for each group ID.

If you have more than one HA cluster on the same network, each cluster should have
a different group ID. If two clusters on the same network have the same group ID, the
duplicate MAC addresses cause addressing conflicts on the network.

Unit Priority

Optionally set the unit priority of the cluster unit. Each cluster unit can have a different
unit priority (the unit priority is not synchronized among cluster members). During HA
negotiation, the unit with the highest unit priority becomes the primary cluster unit. The
unit priority range is 0 to 255. The default unit priority is 128.

Active-Active

Load balancing and failover HA. Each cluster unit actively processes

connections and monitors the status of the other FortiGate units in the cluster.

The primary FortiGate unit in the cluster controls load balancing among all of

the cluster units.

Active-Passive Failover HA. The primary FortiGate unit in the cluster processes all

connections. All other FortiGate units in the cluster passively monitor the

cluster status and remain synchronized with the primary FortiGate unit.

Table 3: HA group ID and MAC address

Group ID

MAC Address

0

00-09-0f-06-ff-00

1

00-09-0f-06-ff-01

2

00-09-0f-06-ff-02

3

00-09-0f-06-ff-03

...

63

00-09-0f-06-ff-3f