3 . Provisions for gas connections, top or rear, should be

taken into consideration at time of installation .

4 . If the unit is to be mounted on a non-combustible wall

contact the local authorities for local codes .

5 . Position, level, and mark location of the assembled wall

mount kit .

6 . Drill wall (locating studs if necessary) to accept suitable

fastening devices .

7 . Drill the angle iron bars of the wall mounting kit to match

those drilled in the wall .

8 . Install wall mounting kit to wall .

9 . Install and secure broiler with bolts supplied .

Ventilation and Air Supply

Proper ventilation is highly important for good operation .

The ideal method of ventilation for a Salamander Broiler is

the use of a properly designed canopy hood which should

extend six inches (6”, 152mm) beyond all sides of the

appliance and six (6) feet six (6) inches (1981mm)from the

floor .

A strong exhaust fan will create a vacuum in the room . For

an exhaust system to work properly, replacement air must

enter the room in which the vent is located . The amount

of air which is exhausted must equal the amount entering,

(make-up air) .

All gas burners and pilots need sufficient air to operate and

large objects should not be placed in front or on top of the

broiler which would obstruct the air flow through the front of

the broiler .

The following notes are intended to give general guidance .

For detailed recommendations, refer to the applicable

code(s) in the country of destination .

NOTE 1: The room containing the appliance is required to

have a permanent air vent . The minimum effective area of

the vent is related to the maximum rated heat input of the

appliance and shall be 4 .5 cm² per kW (2 .04 X 10-4 in² per

BTU/H) in excess of 7 kW . (23,900 BTU/H) .

NOTE 2: Air vents should be of such a size to compensate for

the effects of any extract fan in the premises .

FOR YOUR SAFETY never place any type of object on top of

the salamander broiler . The top of the broiler will exceed

1000° F (538° C) . It could cause severe burns and/or fire

and also will obstruct ventilation .

Clearances

Clearance must be 6” (152mm) at the sides and rear from

combustible material . A clearance of 0 .0” to non combustible

construction at the sides & rear is acceptable, for the

Salamander .

This appliance is for use on non-combustible floors/counters

only .

INSTALLATION Continued