Hydraulic Diagrams

9

4 Hydraulic Diagrams

4.1 S-Plan Type - Monovalent

4.2 Extended S-Plan Type - Monovalent

Heat Pump

ATC

Heat Pump

ATC

Flow

Flexible

pipe

Auto

Bypass

Isolating

valve

Isolating

valve

Return

CH Flow

DHW Flow

CH Retur

n

DHW Retur

n

CH Retur

n

DHW Retur

n

Cylinder
Stat

Room
Stat

Internal wiring

centre

Heating Load

Heating Load

Heating Load

Programmer

Grant Aerona

Heat Pump

Primary

Pump

Condenser

CH Flow

DHW Flow

Cylinder
Stat

Room
Stat

Internal wiring

centre

Programmer

Figure 4-1: Monovalent system - with S-Plan type controls

Figure 4-2: Monovalent system - with extended S-Plan type controls

Outside

wall

Outside

wall

Flow

Flexible

pipe

Auto

Bypass

Isolating

valve

Isolating

valve

Return

Grant Aerona

Heat Pump

Primary

Pump

Condenser

The following are examples of suitable systems

IMPORTANT

The following system diagrams
are only concept drawings and
not detailed engineering
drawings. They are not intended
to describe complete systems,
nor any particular system.

It is the responsibility of the
system designer, not Grant
Engineering UK Ltd., to
determine the necessary
components for and
configuration of the particular
system being designed including
any additional equipment and
safety devices to ensure
compliance with building and
safety code requirements.