Earth connections have
been excluded for clarity.
Ensure all earth
connections are made
prior to energising.

Within the heat pump control panel, connect the wires as follows:

Wiring Centre

Heat Pump

8

1 – Common

9

2 – Heating

10

3 – DHW

For multiple heating zone valves, follow the above and join all oranges from the
heating motorised valves into 9 in the wiring centre, and all greys to terminal 8.

Hlg Zone V

alve

DHW Zone V

alve

E

L

N

L

N

E

4

5

6

7

8

9

10

1

2

3

1

Limit

Control

2

c

1

2

c

Programmer

Room

Thermostat

CH

HW

Gr

Br

O

Bl

Off

E

Gr

Br

O

Bl

Off

Note that both wires from Gr (grey)
now terminate on their own at
position 8. The wires from O (orange)
from each valve now terminate on
their own at positions 9 and 10. The
feed from the cylinder thermostat
and the feed to Br (brown) on the
DHW motorised valve, now
terminates at position 7. When that
is completed, the 3-core 0.75mm²
cable can now connect at positions
8, 9 and 10.

!

NOTE

Figure 8-2: S-Plan type system for connection to Aerona heat pump