Fault finding – Grant Products HPAW155 User Manual

Page 41

Advertising
background image

Fault Finding

37

13.2 General Notes

1. If no continuity can be found

between terminals 1 & 2 and/or 1
& 3 there will be a fault within the
heating s-plan system. (see diagram
for location of the terminals.)

2. Please go back to your design of

the S-plan wiring and check it
against the installation manual.
In detail, trace the demand for CH
and DHW in isolation, covering the
programmer, room or cylinder
thermostats, motorised valves and
end switches. Make sure that when
the end switches of the motorised
valves make, that there is no

voltage present. Voltage on these
wires will do irreparable damage to
the heat pump and will not be
covered by the warranty.

3. WWSD (warm weather shut down)

happens only under 2 conditions.
1 – when the ambient air
temperature is at 24˚C or equal to
the indoor temperature and 2 –
when the CH is the only demand on
the heat pump. WWSD is active
when WWSD appears on the
display of the BTC.

4. MCB’s and RCD can trip for a

variety of reasons. Here are some
common explanations but

remember only qualified electricians
can work on power installations.
If you are in any doubt, call an
electrician – not our helpline – we
will only direct you to call an
electrician.

a)

Incorrect rating or type of
MCB/RCD

b) A component leaking to earth

c)

A component with a dead short

d) Incorrect polarity

e)

Incorrect cable size

f)

Damaged cable or component

Figure 13-1: Heat pump wiring diagram

230 Vac

Compressor

Heater

4-way

valve

Expansion Valve

Disconnect
Electric Element
for Bivalent
Switched Output

For diagram of 6kW immersion
heater refer to Figure 8-9.

Ret Gas Sensor

Ext Temp Sensor

Coil Temp Sensor
Dis Gas Sensor
Ret Temp Sensor

N

Compressor

Fan

motor

Pump

Relay

KM2

3kW

Electric

Element

Orange

Red

Blue

White

Blk

Power Supply

Terminal

3 Connection points for installer

ATC Controller

Socket

S-Plan Controls

Connections

3 2 1

3 2 1

12

11

10

9

8

7

6

5

4

3

2

1

24

23

22

21

20

19

18

17

16

15

14

13

C

R

S

24 Vac

Fuse

Relay KM1

Low pr

essur

e

switch

High pr

essur

e

switch

Advertising