Electrical – Grant Products HPAW155 User Manual
Page 25

Electrical
21
230 Vac
Compressor
Heater
4-way
valve
Expansion Valve
Ret Gas Sensor
Ext Temp Sensor
Coil Temp Sensor
Dis Gas Sensor
Ret Temp Sensor
N
Compressor
Fan
motor
Pump
Relay
KM2
6kW
Electric
Element
Orange
Red
Blue
White
Blk
Power Supply
Terminal
3 Connection points for installer
ATC Controller
Socket
S-Plan Controls
Connections
3 2 1
3 2 1
12
11
10
9
8
7
6
5
4
3
2
1
24
23
22
21
20
19
18
17
16
15
14
13
C
R
S
24 Vac
Fuse
Relay KM1
Low pr
essur
e
switch
High pr
essur
e
switch
Figure 8-9: Heat pump connection diagram for 6kW electrical element
Model
3kW Immersion Heater
6kW Immersion Heater
MCB
MCB
MCB
MCB
P
In
(W)
I
Start
(A)
I
Run
(A)
V
Hz
I
Start
I
Run
(A)
Type
I
Start
I
Run
(A)
Type
HPAW65
1620 22.09 7.36 220 50
35.09 20.36 32 D
49.09 34.36
40
D
HPAW85 2200
30.00
10.00
220
50 43.00
23.00
32 D 57.00
37.00 40 D
HPAW110
2610
35.59
11.86
220
50
48.59
24.86
32
D
62.59
38.86
40 or 50
D
HPAW130
2590
35.32
11.77
220
50
48.32
24.77
32
D
62.32
38.77
40 or 50
D
HPAW155 2770 37.77 12.59 220 50
50.77 25.59 32 D
64.77 39.59 50
D
Model
3kW Immersion Heater
6kW Immersion Heater
MCB
MCB
MCB
MCB
P
In
(W)
I
Start
(A)
I
Run
(A)
V
Hz
I
Start
I
Run
(A)
Type
I
Start
I
Run
(A)
Type
HPAW65
1770 23.09 7.70 230 50
36.09 20.70 32 D
50.09 34.70
40
D
HPAW85 2404
31.36
10.45
230
50 44.36
23.45
32 D 58.36
37.45 40 D
HPAW110 2852 37.20 12.40 230 50
50.20 25.40 32 D
64.20 39.40 50
D
HPAW130 2830 36.91 12.30 230 50
49.91 25.30 32 D
63.91 39.30 50
D
HPAW155 3028 39.50 13.17 230 50
52.50 26.17 32 D
66.50 40.17 50
D
Assumptions: 1. 30m run from consumer box to heat pump
2. Cable not run in thermally insulated environment: Method A and C only (17th edition)
3. Starting current assumes 3x running current
4. Earth Loop Impedence value does not exceed 0.36
W for a D type MCB
IMPORTANT: ENSURE INCOMING SUPPLY CABLE AND SUPPLY FUSE ARE OF SUITABLE SIZE
The 6kW immersion
element is ONLY available
as a factory fitted option