Multi-Tech Systems ISI5634PCI/4/8 User Manual

Page 80

Advertising
background image

80

ISI5634PCI/4/8 User Guide

I11

Display diagnostic information for the last modem con-

nection, such as DSP and firmware version, link type,

line speed, serial speed, type of error correction/data

compression, number of past retrains, etc.

Command: Nn

Modulation Handshake

Values:

n = 0 or 1

Default:

1

Description: N0

Modem performs handshake only at communication

standard specified by S37 and the B command.

N1

Modem begins handshake at communication standard

specified by S37 and the B command. During hand-

shake, fallback to a lower speed can occur.

Command: On

Return Online to Data Mode

Values:

0, 1, 3

Default:

None

Description: O0

Exit online command mode and return to data mode (see

+++AT<cr> escape sequence ).

O1

Issue a retrain and return to online data mode.

O3

Issue a rate renegotiation and return to data mode.

Command: P

Pulse Dialing

Values:

P, T

Default:

T

Description:

Configures the modem for pulse (non-touch-tone)

dialing. Dialed digits are pulsed until a T command or

dial modifier is received.

Command: Qn

Result Codes Enable/Disable

Values:

n = 0 or 1

Default:

0

Description: Q0

Enable result codes.

Q1

Disable result codes.

Q2

Returns an OK for backward compatibility with some

software.

Advertising