ISI5634PCI/4/8 User Guide

Command: Xn

Result Code Selection

Values:

n = 0–7

Default:

4

Description: X0

Basic result codes (e.g., CONNECT); does not look for

dial tone or busy signal.

X1

Extended result codes (e.g., CONNECT 46000 V42bis);

does not look for dial tone or busy signal.

X2

Extended result codes with NO DIALTONE; does not

look for busy signal.

X3

Extended result codes with BUSY; does not look for dial

tone.

X4

Extended result codes with NO DIALTONE and BUSY.

X5

Extended result codes with NO DIALTONE and BUSY.

X6

Extended result codes with NO DIALTONE and BUSY.

X7

Basic result codes with NO DIALTONE and BUSY.

Command: Yn

Long Space Disconnect

Values:

n = 0

Default:

0

Description: Y0

Disable sending or responding to long space break

signal on disconnect.

Y1

Enable sending or responding to long space break sig-

nal on disconnect. (Not supported.)

Command: Zn

Modem Reset

Values:

n = 0 or 1

Default:

None

Description: Z0

Resets modem to profile saved by last &W command.

Z1

Same as Z0.

Command: &Bn V.32 Auto Retrain

Values:

n = 1

Default:

1

Description: &B0 Disable V.32 auto retrain. (Not supported.)

&B1 Enable V.32 auto retrain.