Multi-Tech Systems ISI5634PCI/4/8 User Manual

Page 85

Advertising
background image

85

Chapter 4—AT Commands, S-Registers, Result Codes

Command: &Tn V.54 Test Commands

Values:

n = 0, 1, 3 or 6

Default:

None

Description: &T0 Abort. Stop any test in progress.

&T1 Local analog loopback test.

&T3 Local digital loopback test.

&T6 Remote digital loopback test.

Note: To stop a test, you must use the escape sequence

(+++AT) before typing AT&T0.

Command: &V Display Current Settings

Values:

n/a

Description:

Displays the active modem settings, including the

callback security settings if callback security is enabled.

If the setup password has been entered, it also displays

the callback security passwords.

Command: &Wn Store Current Configuration

Values:

n = 0

Default:

None

Description: &W0 Stores current modem settings in nonvolatile memory

and causes them to be loaded at power-on or following

the ATZ command instead of the factory defaults. See

also the &F command.

&W1 Clears user default settings from nonvolatile memory

and causes the factory defaults to be loaded at power-

on or following the ATZ command.

Command: &Yn Select Stored Configuration for Hard Reset

Values:

n = 0

Default:

0

Description: &Y0 Select stored configuration 0 on power-up. (For

backward compatibility with some software.)

&Y1 Not supported—responds ERROR.

Advertising