Installation, Caution – Manitowoc Ice CM MODEL STH003 User Manual

Page 13

Advertising
background image

13

INSTALLATION

LOCATION OF ICE MACHINE
The location selected for the ice machine must meet
the following criteria. If any of these criteria are not
met, select another location.

The location must be indoors.

The location must be free of airborne and other
contaminants.

Air temperature: must be at least 50ºF (10ºC) but
must not exceed 110ºF (43ºC).

The location must not be near heat-generating
equipment or in direct sunlight.

The location must be capable of supporting the
weight of the ice machine and a full bin of ice.

The location must allow enough clearance for
water, drain, and electrical connections in the rear
of the ice machine.

The location must not obstruct airflow through or
around the ice machine (condenser airflow is in
and out the front). Refer to the chart below for
clearance requirements.

Self-Contained

Air-Cooled

Self-Contained

Water-Cooled

Top/Sides

5" (127 mm)*

5" (127 mm)*

Back

5" (127 mm)*

5" (127 mm)*

*NOTE: The ice machine may be built into a cabinet.
There is no minimum clearance requirement for the top
or left and right sides of the ice machine. The listed
values are recommended for efficient operation and
servicing only.

CAUTION

The ice machine must be protected if it will be
subjected to temperatures below 32 F (0 C). Failure
caused by exposure to freezing temperatures is not
covered by the warranty.

Advertising