COMPONENT SPECIFICATIONS AND

CHECK PROCEDURES

MAIN FUSE
Function

The control board fuse stops ice machine operation if
electrical components fail causing high amp draw.
Specifications

Volt

Amp

CM50 250

10


Check Procedure

WARNING

High (line) voltage is applied to the control
board at all times. Removing the control
board fuse or moving the toggle switch to
OFF will not remove the power supplied to
the control board.

1. If the bin switch light is on with the ice damper

closed, the fuse is good.

WARNING

Disconnect electrical power to the entire ice
machine before proceeding.

2. Remove the fuse. Check the resistance across the

fuse with an ohmmeter.

Reading Result

Open (OL)

Replace fuse

Closed (O)

Fuse is good