CLEANING PROCEDURE

Ice machine cleaner is used to remove lime scale and
other mineral deposits. Ice machine sanitizer disinfects
and removes algae and slime.

NOTE: All ice must be removed from the bin.

Step 1 Prepare 4 oz (1/2 cup) of undiluted Manitowoc
Ice Machine Cleaner (part number 000000084 only) in
a container that will fit easily under the lifted water
shutters. Refer to page 3-1 to identify the water
shutters.

Step 2 Press the Clean switch. The ice machine will
initiate a 2 minute harvest to remove any remaining ice
from the evaporator.

Step 3 Remove all ice from the bin.

Step 4 Wait 3 minutes until the Clean light flashes,
then add the prepared Manitowoc Cleaner by lifting the
water shutters and pouring directly into the spray area.
The ice machine will automatically time out a ten
minute cleaning cycle, followed by eight rinse cycles,
and stop. The Clean light will turn off to indicate the
clean cycle is complete. This entire cycle lasts
approximately 30 minutes.

Step 5 When the cleaning process stops, disconnect
power and remove all parts as described in Removal of
Parts for Cleaning and Sanitizing.

Step 6 Mix 16 oz (2 cups) cleaner with 2 gal of warm
water.

CAUTION

Do not mix Cleaner and Sanitizer solutions
together. It is a violation of Federal law to use
these solutions in a manner inconsistent with
their labeling.