DISCHARGE PRESSURE HIGH CHECKLIST

Problem

• Cause

Improper Installation

•

Refer to “Installation/Visual Inspection Checklist”

Restricted Condenser Air Flow

•

High inlet air temperature

•

Condenser discharge air re-circulation

•

Dirty condenser fins

• Defective

fan

motor

Improper Refrigerant Charge

• Overcharged

•

Non-condensable in system

•

Wrong type of refrigerant

Other

•

Non-Manitowoc components in system

•

High side refrigerant lines/component restricted
(before mid-condenser)

FREEZE CYCLE DISCHARGE PRESSURE LOW
CHECKLIST

Problem

• Cause

Improper Installation

•

Refer to “Installation/Visual Inspection Checklist”

Improper Refrigerant Charge

• Undercharged

•

Wrong type of refrigerant

Other

•

Non-Manitowoc components in system

•

High side refrigerant lines/component restricted
(after condenser)

•

Ambient temperature too low

NOTE: Do not limit your diagnosis to only the items
listed in the checklists.