Manitowoc Ice CM MODEL STH003 User Manual

Page 48

Advertising
background image

48

DISCHARGE PRESSURE HIGH CHECKLIST

Problem

• Cause

Improper Installation

Refer to “Installation/Visual Inspection Checklist”

Restricted Condenser Air Flow

High inlet air temperature

Condenser discharge air re-circulation

Dirty condenser fins

• Defective

fan

motor

Improper Refrigerant Charge

• Overcharged

Non-condensable in system

Wrong type of refrigerant

Other

Non-Manitowoc components in system

High side refrigerant lines/component restricted
(before mid-condenser)

FREEZE CYCLE DISCHARGE PRESSURE LOW
CHECKLIST

Problem

• Cause

Improper Installation

Refer to “Installation/Visual Inspection Checklist”

Improper Refrigerant Charge

• Undercharged

Wrong type of refrigerant

Other

Non-Manitowoc components in system

High side refrigerant lines/component restricted
(after condenser)

Ambient temperature too low

NOTE: Do not limit your diagnosis to only the items
listed in the checklists.

Advertising