EXAMPLES OF HOT GAS VALVE

INLET/COMPRESSOR DISCHARGE LINE

TEMPERATURE COMPARISON

Findings Comments

The inlet of the

hot gas valve is

cool enough to

touch and the

compressor

discharge line is

hot.

This is normal as the discharge

line should always be too hot to

touch and the hot gas valve

inlet, although too hot to touch

during harvest, should be cool

enough to touch after 5 minutes

into the freeze cycle.

The inlet of the

hot gas valve is

hot and

approaches the

temperature of

a hot

compressor

discharge line.

This is an indication something

is wrong, as the hot gas valve

inlet did not cool down during

the freeze cycle. If the

compressor dome is also

entirely hot, the problem is not

a hot gas valve leaking, but

rather something causing the

compressor (and the entire ice

machine) to get hot.

Both the inlet of

the hot gas

valve and the

compressor

discharge line

are cool enough

to touch.

This is an indication something

is wrong, causing the

compressor discharge line to

be cool to the touch. This is not

caused by a hot gas valve

leaking.