ADJUSTING CUBE WEIGHT
The cube weight can be increased from the factory
setting by adjusting the finish time.

Additional finishing time check:

Press and hold the power button for 5 seconds.

Count the flashes on the Automatic Ice
Making light. The light will flash once for each
additional minute of freeze cycle time.

Adjusting Finishing Time

Adjust in 1-minute increments and allow the ice
machine to run several freeze/harvest cycles, and then
inspect the ice cubes. If a heavier cube weight is
desired add another minute of freeze time and repeat
the process.

Press and hold the power button.

Press and release the clean button once for
each additional minute of freeze cycle time
desired.

Five minutes is the maximum additional freeze time
that can be added. Pressing the clean button 6 times
will reset the finishing time to zero additional minutes.