Caution – Manitowoc Ice CM MODEL STH003 User Manual

Page 38

Advertising
background image

38

REMOVAL FROM SERVICE/LONG TERM
STORAGE/WINTERIZATION
GENERAL
Special precautions must be taken if the ice machine is
to be removed from service for an extended period of
time or exposed to ambient temperatures of 32

°F (0°C)

or below.

CAUTION

If water is allowed to remain in the ice machine
in freezing temperatures, severe damage to
some components could result. Damage of this
nature is not covered by the warranty.

Follow the applicable procedure below.

SELF-CONTAINED AIR-COOLED ICE MACHINES
1. Perform a cleaning and sanitizing procedure to

prevent mildew growth.

2. Disconnect the electric power at the circuit breaker

or the electric service switch.

3. Turn off the water supply.
4. Remove the water from the water trough.
5. Disconnect and drain the incoming ice-making

water line at the rear of the ice machine.

6. Blow compressed air in both the incoming water

and the drain openings in the rear of the ice
machine until no more water comes out of the inlet
water lines or the drain.

7. Make sure water is not trapped in any of the water

lines, drain lines, distribution tubes, etc.

8. Block the door partially open to provide air

exchange and prevent mildew growth.

Advertising