AIR-COOLED CONDENSER
A dirty condenser restricts airflow, resulting in
excessively high operating temperatures. This reduces
ice production and shortens component life. Clean the
condenser at least every six months. Follow the steps
below.

WARNING

The condenser fins are sharp. Use care when
cleaning them.

1. The washable aluminum filter on self-contained

air-cooled ice machines is designed to catch dust,
dirt, lint and grease. This helps keep the
condenser clean. Clean the filter with a mild soap
and water solution.

2. Clean the outside of the condenser with a soft

brush or a vacuum with a brush attachment. Clean
from top to bottom, not side to side. Be careful not
to bend the condenser fins.

3. Shine a flashlight through the condenser to check

for dirt between the fins. If dirt remains:
a) Blow compressed air through the condenser

fins from the inside. Be careful not to bend the
fan blades.

b) Use a commercial condenser coil cleaner.

Follow the directions and cautions supplied
with the cleaner.

4. Straighten any bent condenser fins with a fin

comb.

5. Carefully wipe off the fan blades and motor with a

soft cloth. Do not bend the fan blades. If the fan
blades are excessively dirty, wash with warm,
soapy water and rinse thoroughly.