Ds2100 user's manual (preliminary) – Moog DS2100 User Manual

Page 16

Advertising
background image

DS2100 User's Manual (Preliminary)

SECTION 3: WIRING AND INSTALLATION

PAGE 3-10

Figure 3.2 Typical DS2100 Cable Bend Radius Requirements

The DS2100 must be permanently and reliably connected to Earth and all conductive parts in the IP54 rated enclosure or
cabinet must be permanently connected to Earth. The impedance between the earth terminal and any accessible part of
the enclosure or cabinet should be less than or equal to 0.1

W.

NOTE - The DS2100 Series Servo-drives are system components that must
be installed in the correct manner to ensure that all electromagnetic
compatibility (EMC) requirements are met. (Refer to Section 2 of this User’s
Guide).

The DS2100 must be mounted on a panel with a flat solid surface in a manner
that ensures that EMC earthing requirements are met.

There must be a clean flat conductive surface at all of the mounting points.
Remove paint or other insulating materials and provide conductive corrosion
protection at the mounting points. It is important that there is good high-
frequency bonding between the panel and the DS2100 Servo-drive.
Conductive hex socket head bolts with conductive locking washers should be
used.

Required for

CE-Compliance

Advertising