Ds2100 user's manual (preliminary) – Moog DS2100 User Manual

Page 29

Advertising
background image

SECTION 3: WIRING AND INSTALLATION

DS2100 User's Manual (Preliminary)

PAGE 3-23

3.5.1 Drive Contactor (User Supplied)

A contactor (suitably rated for the particular DS2100 should be installed just before the AC input line filter of the
DS2100. The contactor acts as a remote switch that may cut off the AC mains supply in the event of an emergency
shutdown. This contactor should be sized based on the continuous power of the system.

CAUTION - All external electrical wiring
connected to this equipment must be color coded
in accordance with European Standard EN
60204-1 requirements..

CAUTION - All wires and cables entering and
leaving the IP54 rated enclosures or cabinets
containing the DS2100 Servo-drive and the
Regen resistor(s) must be protected and anchored
in accordance with the requirements of EN
60204-1.

CAUTION - Additional electromagnetic
compatibility (EMC) measures which must be
installed on equipment cables associated with the
DS2100 Servo-drive are given in Section 2 of this
User’s Guide.

Required for

CE-Compliance

Advertising