SECTION 3: WIRING AND INSTALLATION

DS2100 User's Manual (Preliminary)

PAGE 3-69

3.14.3 C Size Power Stage

J9

J8

J6

J7

-

Fixed connector: 5 pins, male connector

-

Mating connector, 5 pins, female, crimped supplied with the drive. (Molex 42816-0512)

-

C size wiring: cable 8 AWG (8.4 mm

2

).

Pos.

Name

Function

J6.1

L3

Phase "L3", ", three-phase voltage input 230/460Vac

±10%

J6.2

L2

Phase "L2", ", three-phase voltage input 230/460Vac

±10%

J6.3

L1

Phase "L1", three-phase voltage input 230/460Vac

±10%

J6.4

DC+(RR)

DC Bus (+) (Regeneration Resistor connection)

J6.5

RR

Regeneration Resistor

-

Fixed connector: 4 pins, male connector

-

Mating connector, 4 pins, female, crimped supplied with the drive. (Molex 42816-0412)

-

C size wiring: cable 8 AWG (8.4 mm

2

).

Pos.

Name

Function

J7.1

U

Motor Phase U

J7.2

V

Motor Phase V

J7.3

W

Motor Phase W

J7.4

PE

Motor Protective Earth

-

Fixed connector: 2 pins, male connector

-

Mating connector, 2 pins, female, supplied with the drive. Wago (Part # 231-102/026-000)

-

C & D size wiring: cable 14 AWG (2.1 mm

2

).

-

Stripping Length 8mm

Pos.

Name

Function

J8.1

24V

+24V Logic Backup Supply

J8.2

0V

Logic Supply Return

-

Fixed connector: 2 pins, male connector

-

Mating connector, 2 pins, female, crimped supplied with the drive. (Molex 42816-0212)

-

C size wiring: cable 8 AWG (8.4 mm

2

).

Pos.

Name

Function

J9.2

DC+

DC Bus (+)

J9.1

DC-

DC Bus (-)

-

PE Stud wiring: cable 6 AWG (13mm

2

)

Pos.

Name

Function

PE

PE

Protective Earth Stud on Chassis