Ds2100 user's manual (preliminary) – Moog DS2100 User Manual

Page 76

Advertising
background image

DS2100 User's Manual (Preliminary)

SECTION 3: WIRING AND INSTALLATION

PAGE 3-70

3.14.4 D Size Power Stage

-

Fixed connector: 4 pole, screw terminal

-

D size wiring: cable 6 AWG (13 mm

2

) for 50/140

-

D size wiring: cable 4 AWG ( 21mm

2

) for 60/180

-

PE Terminal wiring: cable 6 AWG (13 mm

2

) for 50/140

-

PE Terminal wiring: cable 4 AWG (21 mm

2

) for 60/180

-

Stripping Length 16mm

-

Tightening Torque: 2-2.3Nm

Pos.

Name

Function

J9.1

RR

Regeneration Resistance

J9.2

DC+(RR)

DC Bus (+)

J9.3

PE

Protective Earth Screw Terminal

J9.4

L1

Phase "L1", three-phase voltage input 230/460Vac

±10%

J9.5

L2

Phase "L2", ", three-phase voltage input 230/460Vac

±10%

J9.6

L3

Phase "L3", ", three-phase voltage input 230/460Vac

±10%

J9.7

U

Motor Phase U

J9.8

V

Motor Phase V

J9.9

W

Motor Phase W

J9.10

PE

Motor Protective Earth

J9.11

DC+

DC Bus (+)

J9.12

DC-

DC Bus (-)

-

Fixed connector: 2 pins, male connector

-

Mating connector, 2 pins, female, supplied with the drive. Wago (Part # 231-102/026-000)

-

D size wiring: cable 14 AWG (2.1 mm

2

).

-

Stripping Length 8mm

Pos.

Name

Function

J8.1

24V

+24V Logic Backup Supply

J8.2

0V

Logic Supply Return

Advertising