Ds2100 user's manual (preliminary), 2 softstart & power cycling frequency limits – Moog DS2100 User Manual

Page 37

Advertising
background image

SECTION 3: WIRING AND INSTALLATION

DS2100 User's Manual (Preliminary)

PAGE 3-31

3.7.1.4 Size

D

EMC Filter,

Fuses etc.

See

Section 2

Installation

4 5 6

L1 L2 L3

Connector J9

D

3

PE

a.c. Mains

L1

L2

L3

Protective

Earth

Figure 3.18 Size D AC Mains Input Connection

-

Fixed connector: 4 pole, screw terminal

-

D size wiring: cable 6 AWG (13 mm

2

) for 50/140

-

D size wiring: cable 4 AWG ( 21mm

2

) for 60/180

-

PE Terminal wiring: cable 6 AWG (13 mm

2

) for 50/140

-

PE Terminal wiring: cable 4 AWG (21 mm

2

) for 60/180

-

Stripping Length 16mm

-

Tightening Torque: 2-2.3Nm

Pos.

Name

Function

J9.3

PE

Protective Earth Screw Terminal

J9.4

L1

Phase "L1", three-phase voltage input 230/460Vac

±10%

J9.5

L2

Phase "L2", ", three-phase voltage input 230/460Vac

±10%

J9.6

L3

Phase "L3", ", three-phase voltage input 230/460Vac

±10%

Table 3.6 J9 AC Mains Power connector, D Size

3.7.2 Softstart & Power Cycling Frequency Limits

The DS2100 contain an internal soft-start function. The soft-start function limits the inrush current into the DS2100's
D.C. Bus smoothing capacitors after the a.c. mains has been switched on.

If the frequency of power cycling becomes too high, then the power dissipation in the soft-start resistor can be excessive.
In this case the softstart circuitry may become damaged.

CAUTION:- The internal softstart resistors are designed to allow an AC application of
once every 60 seconds. If this rate is exceeded, then the internal softstart resistors may
be damaged.