Troubleshooting procedures, Warning – Maytag MAH9700AW* User Manual
Page 14
 
Troubleshooting Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death, disconnect power to unit before servicing, unless testing
requires power.
14
16025909 Rev. 0
©2005 Maytag Services
#
IN
Test or Display
Press LED to
Start
Press LED to
Cancel
Fast 
Time- 
Down / 
Advance 
to Next 
Step 
Press 
Temperature 
to start test. 
Press 
Temperature 
during cycle to 
advance. 
Press Power 
Off 
Quick 
Service 
Cycle 
Press 
Temperature 
and Soil Level 
Press Off (also 
exits Service 
Mode) 
Hold Quick 
Service Cycle 
Step 
Press 
Rinse&Spin 
and Spin Only 
together 
Press 
Rinse&Spin 
and Spin Only 
to resume 
 
 
 
 
LED/Switch
Test
Press Delay for 
3 seconds (then 
individual 
buttons to test) 
Rotate Cycle 
Selector 
clockwise, the 
LED’s around it 
will be toggled. 
Rotate 
counterclockwis
e, the7-
segment LED’s 
toggle. Press 
Rotary Cycle 
Selector, all of 
the LED’s 
around the 
Rotary Cycle 
Selector will be 
toggled. 
Press Off twice 
after starting 
test 
Board
Input
Test
Press Spin 
Only 
Press Spin 
Only 
 Board 
Output 
Test / 
System Check
Press Spin 
Speed 
Press Off
 
 
 
Diagnostic 
Code Display 
(Initial) 
Press Rinse& 
Spin – displays 
“d” 
Press 
Rinse&Spin 
again 
Test or Display
Press LED to
Start
Press LED to
Cancel
All Diagnostic 
Codes 
Rotate Cycle 
Selector either 
direction 
N/A
Cycle Count 
No. for 
Diagnostic 
Code 
Press and hold 
Rotary 
Selector, while 
diagnostic code 
is displayed 
Release Rotary 
Selector 
(returns to 
diagnostic code 
display) 
Clear All 
Diagnostic 
Codes 
Press Delay 
and Chime 
together while 
displaying 
diagnostic 
codes 
Display 
Software 
Version 
Press Soil 
Level. Press 2 
times for 
displays with 
only 2 character 
positions. 
Press Soil 
Level a 3
rd
time
Cycle Count
Press Chime
Quick Spin Test 
While in Service Mode, press Delay and 
Rinse&Spin keys to start a Quick Spin Test. 
Quick Spin test steps are as follows: 
• Start spinning and after reaching a 
maximum spin speed.
• stay at maximum spin speed for 2
minutes and stop Quick Spin Test.
Hold Quick Spin Step 
If the Rotary Selector key is pressed during 
the Quick Spin test, the machine will hold at 
the next highest index speed for up to 10 
minutes. At the end of 10 minutes, the 
machine will resume and finish the Quick 
Spin test. To cancel the Hold and allow the 
Spin Test to continue, press the Delay and 
Rinse&Spin keys. 
 
2