Troubleshooting Procedures

!

WARNING

To avoid risk of electrical shock, personal injury or death, disconnect power to unit before servicing, unless testing
requires power.

20

16025909 Rev. 0

©2005 Maytag Services

Diag.

Code

Description

Trigger

Action to be

taken

25

Motor tach

signal exists

without

motor

running.

Tach signal

exists without

torque

command or

when not
expected

(Abnormal

condition

only).

Displays " bE".

Replace Machine

Control Board.

26-28 Not

Used

29

Sump

thermistor

failure

(Optional)

Abnormal

high/low temp

or ohm

resistance

seen

Displays " tE".
- Loose or pinched
wires
- Bad sump
thermistor

30-33 Not

Used

2E

Motor Drive

failure

(Locked, Hall

sensor fault)

Machine

control is

attempting to

drive the

motor but is

not seeing

any tach

response.

Visual check

shows motor

is not moving.

Display “E3
Evaluate wire
harness for loose or
unhooked
connections. If
machine has
separate motor
control, perform self
diagnostic motor
test. See “Board
Output Test

34

System

Relay failure

Machine

control does

not see relay
open when it

should.

Display "Sr".
Replace machine
control board.

35 Not

Used

Diag.

Code

Description Trigger

Action

to

be

taken

36

Heater relay

failure.

Heater Relay
Check signal

not sensed.

Display "Hr".

Replace Machine

Control Board.

3E

Motor failure

(Over

current)

Over Current

is detected.
Motor won't

turn.

Displays

"3E".Check the

motor windings, the

speed sensor,

wiring connections,

or Control Board.

40-49 Not

Used

91

Voltage for

motor control

bus is over

specified

limit

Voltage for

motor control

bus is over

limit

Display

"2E".Replace

Machine Control

Board.

92

Voltage for

motor control

specified

limit

Voltage for

motor control

bus is under

specified limit

Display

"2E".Replace

Machine Control

Board.

Exit Service Mode
To exit:

1) Press

Chime and Extra Rinse keys for

3seconds again, or

2) Press

Off,

or

3) Unplug the machine. After five (5) minutes of

inactivity (user key presses) in Service Mode,
the machine will exit the Service Mode and
resume normal operations. Pressing the Off
key will completely exit Service Mode. If a
cycle is running, cancel the cycle. Pressing
the Rotary Selector knob while running a test
will pause the individual test, while remaining
in Service Mode. A power loss during Service
Mode will cancel this mode.