WARNING

!

Reactor Removal

1. Disconnect power supply to unit.
2. Remove Top Cover.
3. Remove single attachment screw on cross brace.
4. Twist Reactor counterclockwise to remove.

NOTE: The reactor coil is wired in series with line 1

internally in the Control Board. An open coil or
loose electrical connection would result in a
“dead” board complaint. A resistance check
across the coil leads should indicate less than 1
ohm.

EMI Filter Removal

1. Disconnect power supply to unit.
2. Remove Top Cover.
3. Loosen 13mm acorn nut and slide EMI Filter out of

bracket.

NOTE: Mark the wire locations on the EMI before

removing the terminals.