Warning, Disassembly procedures – Maytag MAH9700AW* User Manual

Page 36

Advertising
background image

36

16025909 Rev. 0

©2005 Maytag Services

To avoid risk of electrical shock, personal injury or
death; disconnect power to unit before servicing.

Disassembly Procedures

WARNING

!

Outer Tub and Spinner Removal

1. Disconnect power supply to unit.
2. Remove Top Cover.
3. Remove Console.
4. Remove Front Panel.
5. Remove Back Cover.
6. Remove Pump Hose.
7. Remove the Drain Hose
8. Remove the two 13mm bolts securing the Rear Struts

to the base.

9. Rotate the struts up against the bottom of the tub to

ease removal of the tub assembly.

NOTE: The rear struts can be identified by the green

sleeve.

10. Remove two each side 13mm bolts securing Counter

Weights.

NOTE: Torque bolts to 11-22 ft lbs. during installtion.
11. Remove wire harness connectors for the heater,

Themistor and ground.

12. Remove two 13mm bolts securing the Front Struts to

base and rotate up against the bottom of the tub.

13. Insert a board or boards across the bottom of the

washer frame to use as a support when removing the
tub assembly.

1x12 - 32” long