Component Testing Information
!
WARNING
To avoid risk of electrical shock, personal injury or death, disconnect power to unit before servicing, unless testing
requires power.
©2005 Maytag Services
16025909 Rev. 0
21
Illustration Component
Test
Procedure
Results
Thermistor
Unplug harness connector and test 
from wire insertion side. 
Pin #6 and Pin #3 of CN3 
 
 
13000 ohms @ 70F (2.5V DC) 
 
 
 
 
 
 
 
Door Switch
Unplug harness connector and test 
from wire insertion side. 
 
Pin #7 of CN5 and Pin #3 of CN9 
Pin #8 of CN5 and Pin #3 of CN9 
 
 
60 ohms 
60 ohms 
 
 
 
 
 
 
 
 
Water Sensor
Check voltage at Pin #6 and Pin #7 of 
CN3. 
 
Check voltage at Pin #6 and Pin #8 of 
CN3. 
 
Reset water level = 2.5V DC, 25.8 KHz 
 
 
Reset water level = 2.5V DC, 25.8 KHz 
Sump Sensor 
 
Check voltage at Pin #4 and Pin #2 of 
CN8. 
 
Check voltage at Pin #4 and Pin #3 of 
CN8. 
 
0V DC or 3.75V 
 
 
0V DC or 3.75V 
Motor 
 
Unplug harness connector and test 
from wire insertion side. 
 
Pin #1 and Pin #2 of CN9 
Pin #1 and Pin #3 of CN9 
Pin #2 and Pin #3 of CN9 
 
 
 
 
11.6 ohms 
11.6 ohms 
11.6 ohms 
 
 
 
 
 
 
 
 
Drain Pump
During drain check voltage at Pin #1 of 
CN5 and Pin #6 of CN10 
 
120V AC 
 
 
 
 
 
 
 
Water Valves
Unplug harness connector and test 
from wire insertion side. 
 
(Hot valve) Pin #2 of CN5 and Pin #2 
of CN6 
(Pre valve) Pin #3 of CN5 and Pin #2 
of CN6 
(Bleach valve) Pin #4 of CN5 and Pin 
#2 of CN6 
(Main valve) Pin #1 of CN5 and Pin #2 
of CN6 
 
 
 
 
1100 ohms 
 
1100 ohms 
 
1100 ohms 
 
1100 ohms 
 
Heater Relay
During water heat check voltage at Pin 
#1 of CN5 and Pin #2 of RY9 
 
120V AC 
AC Power
Check voltage at Pin #1 and Pin #3 of 
CN5 
 
Check voltage at Pin #1 of CN5 and 
Pin #1 of CN6 
 
120V AC 
 
 
120V AC 
Reactor
Unplug harness connector and test 
from wire insertion side. 
 
Less than 1 ohm