©2005 Maytag Services
in).While in Service Mode follow chart to check 
respective function. 
• When the “Rotary Cycle Selector” is set to
“Super Wash” and the “Rotary Cycle 
Selector” is pressed, the door position will be 
displayed: “OP” if open, “CL” if closed. 
• When the “Rotary Cycle Selector” is set to
“Normal” and the “Rotary Cycle Selector” is 
pressed, the Lock position will be displayed: 
“UL” if unlocked, “LO” if locked. 
• When the “Rotary Cycle Selector” is set to
“Whites ”and the “Rotary Cycle Selector” is 
pressed, the High water level will be 
displayed: “
–
0” if below level, “
–
1” if above
level. The High water level is defined as the 
over flow water level. 
• When the “Rotary Cycle Selector” is set to
“Wrinkle Control” and the “Rotary Cycle 
Selector” is pressed, the Medium water level 
will be displayed: “-0” if below level, “-1” if 
above level. The Medium water level is 
defined as the minimum water level needed to 
turn the heater on. 
• When the “Rotary Cycle Selector” is set to
“Colors” and the “Rotary Cycle Selector” is 
pressed, the Low water level will be displayed: 
“_0” if below level, “_1” if above level. The 
Low water level is defined as the reset water 
level. 
• When the “Rotary Cycle Selector” is set to
“Hand Wash” and the “Rotary Cycle 
Selector” is pressed, the level of Tub 
unbalance will be displayed: “UC” if balanced, 
“UO” if unbalanced. “U0” will be displayed 
during the time when the machine is 
correcting for the unbalance; e.g. slowing 
down to redistribute the load or to get to a 
lower spin speed. Once the situation has 
been corrected (i.e. the load has begun 
tumbling or the lower speed has resulted in an 
acceptable amount of balance); “UC” will 
once again be displayed. 
• When the “Delay” switch pad is pressed, the
water temperature will be displayed in 
Degrees F. 
• When the “Rotary Cycle Selector” is set to
“Delicates” and the “Rotary Cycle Selector” 
is pressed, the water temperature will be 
displayed in degrees C (Celsius). 
 
 
 
 
 
 
 
While in Service Mode follow chart to check 
respective function. 
Selection Function Display
Rotary cycle 
selector set to 
Super Wash. Press 
Rotary Selector 
Knob. 
Door position “OP” or “CL”
Rotary cycle 
selector set to 
Normal. Press 
Rotary Selector 
Knob. 
Lock state
“UL” or “LO”
Rotary cycle 
selector set to 
Whites. Press 
Rotary Selector 
Knob. 
High water 
level 
“
–
0” if below
level. “
–
1” if
above level.
Rotary cycle 
selector set to 
Wrinkle Control. 
Press Rotary 
Selector Knob. 
Medium 
water level 
“
—0
”
if below
level. “—1” if 
above level. 
Rotary cycle 
selector set to 
Colors. Press 
Rotary Selector 
Knob. 
Low water 
level 
“_0” if below 
level. “_1” if 
above level. 
Rotary cycle 
selector set to 
Hand Wash. Press 
Rotary Selector 
Knob. 
Tub balance
“UC” Balanced 
“UO” 
Unbalanced 
Press Delay switch 
pad. 
Water 
temperature 
Degrees F
Rotary cycle 
selector set to 
Delicates. Press 
Rotary Selector 
Knob. 
Water 
temperature 
Degrees C
Board Output Test
While in Service Mode, pressing the Spin
Speed key will begin the Board Output Test.
This test turns on a specified output after a
key press. Pressing the Spin Speed key again
cancels the test. Only one output can be “on” at any 
time. All outputs will be turned off after five (5) 
minutes of inactivity. 
While in Service Mode follow to check respective 
function. 
• When the “Rotary Cycle Selector” is set to
“Super Wash” and the “Rotary Cycle
2