Examples – IBM 6C4 User Manual

Page 144

Advertising
background image

Flag

Description

-l

List the sensors and their values in a text format.

-a

List the sensors and their values in a numerical format. For each sensor, the
following numerical values are displayed as:

token index status measured

value location code

-t token

Specifies the sensor token to query.

-i index

Specifies the sensor index to query.

-v

Indicates to return the sensor measured value. The sensor status is returned
by default.

Examples

The following are examples from this command:

1. Display a list of the environmental sensors:

/usr/lpp/diagnostics/bin/uesensor -l

Sensor = Fan Speed
Status = Normal
Value = 2436 RPM
Location Code = F1
Sensor = Power Supply
Status = Normal
Value = Present and operational
Location Code = V1
Sensor = Power Supply
Status = Critical low
Value = Present and not operational
Location Code = V2

2. Display a list of the environmental sensors in a numerical list:

/usr/lpp/diagnostics/bin/uesensor -a

3 0 11 87 P1
9001 0 11 2345 F1
9004 0 11 2 V1
9004 1 9 2 V2

3. Return the status of sensor 9004, index 1:

/usr/lpp/diagnostics/bin/uesensor -t

9004 -i 1

9

4. Return the value of sensor 9004, index 1:

/usr/lpp/diagnostics/bin/uesensor -t

9004 -i 1 -v

2