Modem configuration sample files, Sample file modem_m0.cfg – IBM 6C4 User Manual

Page 209

Advertising
background image

Modem Configuration Sample Files

Sample File modem_m0.cfg

#

# COMPONENT_NAME: (ESPSETUP) ENTRY SERVICE PROCESSOR SETUP: modem_m0

#

# FUNCTIONS: Modem configuration file specifically for IBM 7852-400

# modem with Auto-Reliable feature. This feature must be turned off

# for Catcher calls. This example uses the AT&F reset command to

# choose the factory defaults.

#

# (C) COPYRIGHT International Business Machines Corp. 1996

# All Rights Reserved

# Licensed Materials - Property of IBM

#

# US Government Users Restricted Rights - Use, duplication or

# disclosure restricted by GSA ADP Schedule Contract with IBM Corp.

#

#

# The modem has configuration switches. They should be set to the

# factory default settings, except switches 11 and 12. These must be

# to UP ("AT" responses) and DOWN (Asynchronous operation), respectively.

ICDelay 1

DefaultTO 10

CallDelay 120

#

# %N Call-Out phone number

%R

Return phone number

#

#

# PROGRAMMING NOTE: No blanks between double quote marks (").

condout:

send "AT&F&E2E0T\r"

# Reset to factory defaults

# Reliable mode

# Echo off

ignore "0\r" or "OK\r\n" timeout 2 # Ignore modem response.

send "AT&E12&E14\r"

# Disable pacing

# Disable data compression

expect "0\r" or "OK\r\n" timeout 2 # Confirm commands successful.

send "AT&SF1&S0S9=1\r"

# DSR independent of CD

# Force DSR on.

# CD respond time=100ms

expect "0\r" or "OK\r\n" timeout 2 # Confirm commands successful.

send "ATV0S0=0\r"

# Numeric response code

# Auto-Answer off

expect "0\r" or "OK\r\n" timeout 2 # Confirm commands successful.

done

connect:

send "ATDT%N\r"

# Tone dialing command.

# %N from Call Home setup.

# Expect a connection response.

expect "33\r" or "31\r" or "28\r" or "26\r" or "24\r" or "21\r" or

"19\r" or "13\r" or "12\r" or "1\r" busy "7\r"

timeout 60

done

retry:

send "A/"

# Repeat the previous command.

# Expect a connection response.

expect "33\r" or "31\r" or "28\r" or "26\r" or "24\r" or "21\r" or

"19\r" or "13\r" or "12\r" or "1\r" busy "7\r"

timeout 60

done

disconnect:

delay 2

# Separate from previous data.