Example:

list timers

Timers:

Complete SNP (sec) = 10

Partial SNP (sec) = 2

Min LSP Gen (sec) = 30

Max LSP Gen (sec) = 900

Min LSP Xmt (sec) = 30

Min Br LSP Xmt (msec) = 33

Waiting Time (sec) = 60

DR ISIS Hello (sec) = 1

ES Config Timer (sec) = 10

Timers:

Indicates the configuration of the OSI timers excluding any per
circuit timers.

Complete SNP

The interval between generation of complete SNPs.

Partial SNP

The minimum interval between sending partial SNPs.

Min LSP Generation/Max LSP Generation

The minimum and maximum intervals between generations of
LSPs.

Min LSP Transmission

The minimum interval between LSP retransmissions.

Min Broadcast LSP Transmission

The minimum interval between LSP retransmissions on a broadcast
circuit.

Waiting Time

The time the update process must delay before entering the ON
state.

DR ISIS Hello

The interval between generations of IS-IS hello PDUs if this router
is a designated router.

ES Config Timer

The minimum interval between that an ES must send a hello packet
each time an interface comes up.

virtual-circuits

Displays information about all X.25 virtual circuits.

Example:

list virtual-circuits

Set

Use the set command to configure the router to run the OSI protocol.

Syntax: