10.4.2 Horizontal Timing
The horizontal timing for Continuous mode, full frame and partial scan is shown below.

DATA OUT

D V A L

CC D Ou t

F V A L

S U B

S G

E E N

1 L V A L p e r i o d

1 c k = 3 3 . 7 5 0 MHz ( 2 9 . 6 3 n s / c k )

L V A L

E x p o s u r e

P e r i o d

Du mmy +

B l a n k

8 6

3 4 3 c k

1 4 2 0 c k

1 3 2 8 c k

1 0 2 4 c k
1 0 7 7 c k

3 4 3 c k

( 2 0 u s )

OB R e s e r v e d

3ck

8 c k

OB

40 ck

1 0 2 4 c k

R e s e r v e d

4 5 c k

3ck 6ck

3 4 3 c k

4c k

6ck

29 ck

29ck

5 9 0 c k

6 7 6 c k

1 0 7 7 c k

1 4 8

9 2

1ck

1

1 0 3 c k

FVAL rising edge

FVAL falling edge

Effective Pixels

1CLK: 1 Pixel clock period OB: Optical black
LVAL is HIGH in the period of optical black and effective video periods
DVAL is HIGH in the effective video period

Fig.35 Horizontal Timing