10.5. Operation Mode

AD-081GE has the following 8 operation modes and OB transfer and ROI modes.

1

Continuous

Pre-selected exposure

2

Edge Pre-Select Trigger

Pre-selected exposure

3

Pulse Width Control Trigger

Pulse width controlled exposure

4

Reset Continuous Trigger

Pre-selected exposure

5

PIV (Particle Image Velocimetry)

6

Sequence EPS

Pre-selected exposure

7

Delayed readout EPS

Pre-selected exposure

8 Delayed readout PWC

Pulse controlled exposure

9

Smearless

Effective for EPS and PWC

10 OB transfer mode

11 ROI mode



10.5.1 Continuous mode
For applications not requiring asynchronous external triggering, this mode should be used for
continuous operation.
For timing details, refer to fig. 33 through fig. 38.

To use this mode

Set function:

Trigger mode

Continuous

Sync mode

Sync, async, High transfer rate, High
dynamic range, High S/N

Output Select

8-bit, 10-bit, 12-bit

Scanning

Full/Partial

Vertical binning

ON/OFF

Shutter

Programmable, Exposure Time Abs,
Auto shutter

Programmable Shutter

0.5L to 792L (1L unit)

Other functions