AD-081GE

55

10.5.5 Particle Image Velocimetry
PIV mode is an independent function and is not to be combined with the High Frame Rate
function, the High Dynamic Range function, or the normal output mode (Sync or Separate). In
this mode, one trigger input provides three consecutive outputs. A strobe light is used for
illumination. PIV has three preset modes.

PIV mode

Exposure time

Trigger Interval

PIV 1

4 µ

1.5 µ

PIV 2

6 µ

1.5 µ

PIV 3

8 µ

1.5 µ

Trigger width 2L( min. ) to 1V ( max.)

PIV Mode

Trigger Input

EEN

Exposure

Video Output

EEN

Exposure

Video Output

SG

SG

1 Frame

4μ

s

1.5

µs

4μ

s

Strobe 1

Strobe 2

Strobe 3

B

W

1

B

W

2

Fig. 48 PIV