3 pulse width control (pwc) trigg, Ad-081ge – JAI AD-081GE User Manual

Page 53

Advertising
background image

AD-081GE

52

10.5.3 Pulse Width Control (PWC) trigger mode
In this mode the accumulation time is equal to the trigger pulse width. Here it is possible to
have a long time exposure. The maximum recommended time is <60 frames.
The accumulation is only LVAL async.
For timing details, refer to fig. 35 through fig. 40 and fig. 45 through fig.46.

To use this mode:
Set function:

Trigger mode

Pulse Width Control (PWC)

Readout mode

Sync, async,

Output Select

8-bit, 10-bit, 12-bit

Scanning

Full/Partial

Vertical binning

ON/OFF

Accumulation

LVAL async

Other functions

Input:

External Trigger

GigE I/F, Hirose 12-pin,Hirose 6-pin

Important Note:
1 The minimum duration of the trigger is 2L. The minimum period of trigger is as follows.

Sync mode:
Sync

Smearless OFF

Exposure time + 792L + 3L

Smearless ON

Exposure time( Min:199L+2L) + 792L + 2L

Sync mode:
Async

Smearless OFF

Exposure time + 792L + 3L

Smearless ON

Exposure time( Min:199L+2L) + 792L + 3L

FVAL(792L) is the FVAL period of continuous operation.

Fig.45 Pulse Width Control LVAL asynchronous